pptp error leads to router reboot

Reported by: arseny Owned by: developers
Priority: normal Milestone: Barrier Breaker 14.07
Component: packages Version: Trunk
Keywords: Cc:

Description

Periodically pptp client reports

anon warn[decaps_gre:pptp_gre.c:324]: short read (-1): Message too long

After that router immediately reboots.
Please see relevant log parts in the file attached.

Attachments (1)

pptpproblem.log (2.4 KB) - added by arseny 7 years ago.

Download all attachments as: .zip

Change History (5)

Changed 7 years ago by arseny

comment:1 Changed 7 years ago by arseny

More symptoms:
It happens particularly when pptp carrying connection is lost, not in this router, but in the upstream router (this one doesn't know about the loss by itself).

comment:2 Changed 7 years ago by arseny

Another symptom: most often it happens when ssh or rdp session is started from client on near side of the pptp tunnel. MPPE compression buffer overflow on heavily compressed streams? MSS clamping concern?

BTW, how to promote the ticket for it to have higher priority?

comment:3 Changed 6 years ago by nbd

  • Resolution set to worksforme
  • Status changed from new to closed

fixed in recent versions

comment:4 Changed 4 years ago by jow

  • Milestone changed from Attitude Adjustment 12.09 to Barrier Breaker 14.07

Milestone Attitude Adjustment 12.09 deleted