Modify

Opened 3 years ago

Closed 3 years ago

#18278 closed defect (fixed)

serial console login not working

Reported by: anonymous Owned by: developers
Priority: normal Milestone: Chaos Calmer 15.05
Component: base system Version: Trunk
Keywords: procd serial console login Cc:

Description

Changeset 43147 break serial console login

failsave login = working
normal running login = break

Attachments (0)

Change History (8)

comment:1 Changed 3 years ago by Zajec

Link: r43147

comment:2 Changed 3 years ago by cyrus

  • Resolution set to too_vague
  • Status changed from new to closed

comment:3 Changed 3 years ago by anonymous

to vague ..

revert the revert fix it !

comment:4 Changed 3 years ago by anonymous

  • Resolution too_vague deleted
  • Status changed from closed to reopened

with procd form 30.10.2014 over usb ttl serial console login is working
with the versio from 1.11.2014 console not usetable only failsave is working

comment:5 Changed 3 years ago by anonymous

break console on ar711 mips

comment:6 Changed 3 years ago by anonymous

sory trac is very lagy
break ar71xx / mips
there is no message console "Please press Enter to activate this console"

version from 30.10 login is working but no print output root@hontame on login

comment:7 Changed 3 years ago by cyrus

simply reverting the revert will just break another platform.
i've contacted the original author of the patch and he will work on fix for it.

comment:8 Changed 3 years ago by cyrus

  • Resolution set to fixed
  • Status changed from reopened to closed

Fixed in r43178.

Add Comment

Modify Ticket

Action
as closed .
The resolution will be deleted. Next status will be 'reopened'.
Author


E-mail address and user name can be saved in the Preferences.

 