Modify

Opened 5 years ago

Closed 5 years ago

#13744 closed defect (worksforme)

Hardware buttons trigger failsafe but telnet access won't work

Reported by: anonymous Owned by: developers
Priority: highest Milestone: Chaos Calmer 15.05
Component: base system Version: Trunk
Keywords: Cc:

Description

r37015 build for WZR-HP-G300NH (RTL8366S switch)

failsafe triggered using wps button (led blinkrate changes accordingly)

Unable to telnet to failsafe router ip 192.168.1.1 from a host with a static ip in the same subnet

Attachments (0)

Change History (3)

comment:1 Changed 5 years ago by anonymous

same kind of problem here with brcm47xx and seems like someone else experiences this too - http://eko.one.pl/forum/viewtopic.php?id=6363

log file shows following switch errors but only when entered failsafe mode:

Press the [f] key and hit [enter] to enter failsafe mode
f
[ 8.056000] b44 ssb0:0: eth0: powering down PHY
[ 8.064000] roboswitch: failed to write mdio reg: 24 with err -22.
[ 8.072000] roboswitch: failed to write mdio reg: 16 with err -22.
[ 8.080000] roboswitch: failed to write mdio reg: 17 with err -22.
[ 8.084000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.092000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.096000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.104000] roboswitch: timeout in robo_reg on page 52 and reg 16 with op 1.
[ 8.112000] roboswitch: failed to write mdio reg: 24 with err -22.
[ 8.116000] roboswitch: failed to write mdio reg: 16 with err -22.
[ 8.124000] roboswitch: failed to write mdio reg: 17 with err -22.
[ 8.132000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.136000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.144000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.148000] roboswitch: timeout in robo_reg on page 52 and reg 18 with op 1.
[ 8.156000] roboswitch: failed to write mdio reg: 24 with err -22.
[ 8.164000] roboswitch: failed to write mdio reg: 16 with err -22.
[ 8.172000] roboswitch: failed to write mdio reg: 17 with err -22.
[ 8.176000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.184000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.188000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.196000] roboswitch: timeout in robo_reg on page 52 and reg 20 with op 1.
[ 8.204000] roboswitch: failed to write mdio reg: 24 with err -22.
[ 8.208000] roboswitch: failed to write mdio reg: 16 with err -22.
[ 8.216000] roboswitch: failed to write mdio reg: 17 with err -22.
[ 8.224000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.228000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.236000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.244000] roboswitch: timeout in robo_reg on page 52 and reg 22 with op 1.
[ 8.248000] roboswitch: failed to write mdio reg: 24 with err -22.
[ 8.256000] roboswitch: failed to write mdio reg: 16 with err -22.
[ 8.264000] roboswitch: failed to write mdio reg: 17 with err -22.
[ 8.268000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.276000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.280000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.288000] roboswitch: timeout in robo_reg on page 52 and reg 24 with op 1.
[ 8.296000] roboswitch: failed to write mdio reg: 24 with err -22.
[ 8.304000] roboswitch: failed to write mdio reg: 16 with err -22.
[ 8.308000] roboswitch: failed to write mdio reg: 17 with err -22.
[ 8.316000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.320000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.328000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.336000] roboswitch: timeout in robo_reg on page 52 and reg 26 with op 1.
[ 8.340000] roboswitch: failed to write mdio reg: 24 with err -22.
[ 8.348000] roboswitch: failed to write mdio reg: 25 with err -22.
[ 8.356000] roboswitch: failed to write mdio reg: 16 with err -22.
[ 8.360000] roboswitch: failed to write mdio reg: 17 with err -22.
[ 8.368000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.376000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.380000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.388000] roboswitch: timeout in robo_reg on page 52 and reg 8 with op 1.
[ 8.396000] roboswitch: failed to write mdio reg: 24 with err -22.
[ 8.400000] roboswitch: failed to write mdio reg: 16 with err -22.
[ 8.408000] roboswitch: failed to write mdio reg: 17 with err -22.
[ 8.412000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.420000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.428000] roboswitch: failed to read mdio reg 17 with err -22.
[ 8.432000] roboswitch: timeout in robo_reg on page 52 and reg 6 with op 1.
[ 8.484000] b44 ssb0:0: eth0: Link is up at 100 Mbps, full duplex
[ 8.488000] b44 ssb0:0: eth0: Flow control is off for TX and off for RX

  • failsafe -

comment:2 Changed 5 years ago by anonymous

I tested r37077 build for WZR-HP-G300NH (RTL8366S switch) and I was able to telnet after triggering failsafe.

comment:3 Changed 5 years ago by nbd

  • Resolution set to worksforme
  • Status changed from new to closed

Add Comment

Modify Ticket

Action
as closed .
The resolution will be deleted. Next status will be 'reopened'.
Author


E-mail address and user name can be saved in the Preferences.

 
Note: See TracTickets for help on using tickets.