Description

Hi.

I got Vodafone DSL-EasyBox 802 (ARV752DPW-B-LF-IR). u-boot for this board could not detect switch making this bootloader quite useless. Tested on trunk u-boot. Logs below:

[DANUBE Boot]:y

Go to Memory Address: (default:0x80002000) : 0x
Jump to address 0x80002000 ...


U-Boot 2010.03 (Dec 08 2011 - 13:45:25)

Board: ARV752DPW
SoC: Danube/Twinpass/Vinax-VE V1.5, DDR Speed 166 MHz, CPU Speed 333 MHz
DRAM:  64 MB
Flash:  8 MB
*** Warning - bad CRC, using default environment

Net:
searching for rtl8306 switch ... failed

no known switch found ...
lq_cpe_eth
Hit any key to stop autoboot:  0
ARV752DPW =>

Any chances for fix?

Attachments (0)

Change History (3)

comment:1 Changed 6 years ago by dk

Seems that problem is only with uboot-lantiq-arv7525PW_brnboot. The bootstrap uboot-lantiq-arv7525PW_flash detects switch properly. Why is that? Anyways, its not much important so feel free to close the ticket. Now I have this problem, pls take a look: /ticket/10657.html

comment:2 Changed 6 years ago by blogic

  • Resolution set to obsolete
  • Status changed from new to closed

comment:3 Changed 4 years ago by jow

  • Milestone changed from Attitude Adjustment 12.09 to Barrier Breaker 14.07

Milestone Attitude Adjustment 12.09 deleted