Changeset 27973


Ignore:
Timestamp:
2011-08-13T23:49:46+02:00 (6 years ago)
Author:
nbd
Message:

ar71xx: on ar724x only reset the link status in the restart handler, the fast reset takes care of DMA stuck issues

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/target/linux/ar71xx/files/drivers/net/ag71xx/ag71xx_main.c

    r27896 r27973  
    796796        struct ag71xx *ag = container_of(work, struct ag71xx, restart_work); 
    797797 
     798        if (ag71xx_get_pdata(ag)->is_ar724x) { 
     799                ag->link = 0; 
     800                ag71xx_link_adjust(ag); 
     801                return; 
     802        } 
     803 
    798804        ag71xx_stop(ag->dev); 
    799805        ag71xx_open(ag->dev); 